-- SECTION 1: Top Level Definitions

SYNOPTICS-COMMON-MIB DEFINITIONS ::= BEGIN

-- Common MIB Release 4.7.4
-- Revision 05/29/95

-- Copyright 1995 Bay Networks, Inc.
-- All rights reserved.
-- This Bay Networks SNMP Management Information Base Specification
-- (Specification) embodies Bay Networks' confidential and
-- proprietary intellectual property. Bay Networks retains all
-- title and ownership in the Specification, including any
-- revisions.

-- This Specification is supplied "AS IS," and Bay Networks makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.


-- Imports

IMPORTS
	Counter, Gauge, TimeTicks, IpAddress
		FROM RFC1155-SMI
	DisplayString
		FROM RFC1213-MIB
	OBJECT-TYPE
		FROM RFC-1212
	s3SnmpAgent, series3000, SnpxBackplaneType, SnpxChassisType
		FROM SYNOPTICS-ROOT-MIB;


-- Textual Conventions

S3ModuleType ::= INTEGER {
	empty(1),		-- nothing installed
	other(2),		-- none of the following
	m3302(3),		-- STP ethernet Host Module
	m3304-ST(4),		-- FOIRL ethernet Host Module
	m3305(5),		-- UTP ethernet Host Module
	m3308(6),		-- 10 base-T ethernet Host Module
	m3313(7),		-- AUI ethernet NMM w/ RS232 port
	m3313M(8),		-- AUI ethernet NMM w/ RS232 + modem
	m3314-ST(9),		-- FOIRL ethernet NMM w/ RS232
	m3314M-ST(10),		-- FOIRL ethernet NMM w/ RS232 + modem
	m3323(11),		-- AUI Local Bridge
	m3324-ST(12),		-- FOIRL Local Bridge
	m3502(13),		-- STP Token Ring Host Module
	m3532(14),		-- STP Token Ring Repeater
	m3552(15),		-- STP Ring in/ Ring out Module
	m3301(16),		-- Thin Net ethernet Host Module
	m3307(17),		-- 10 base-T 50 pin Host Module
	m3356(18),		-- Ethernet Remote Bridge
	m3512(19),		-- T.R. NMM w/ STP ring in/ring out
	m3514(20),		-- T.R. NMM w/ FOIRL ring in/ring out
	m3505(21),		-- UTP Token Ring Host Module
	m3554(22),		-- FOIRL ring in/ring out Module
	m3534(23),		-- FOIRL Repeater
	m3383(24),		-- AUI ethernet Local Router
	m3384(25),		-- FOIRL ethernet Local Router
	m331x(26),		-- ethernet NMM module w/unknown MDA type
	m351x(27),		-- t.r. NMM module w/unknown MDA type
	m3502-A(28),		-- STP Token Ring Host Module
	m3902(29),		-- STP FDDI Host Module
	m3904(30),		-- Fiber FDDI Host Module
	m3910S(31),		-- FDDI Super NMM
	m3386(32),		-- Cisco Remote Router
	m3394(33),		-- Ethernet-localtalk router
	m3395(34),		-- XYPLEX terminal server
	m3323S(35),		-- High Speed Local Bridge with AUI
	m3324S-ST(36),		-- High Speed Local Bridge with FOIRL
	m3307A(37),		-- 10baseT with amp connector
	m3308A(38),		-- 10baseT (Ibid)
	m3505A(39),		-- UTP Token Ring Host Module
	m3513(40),		-- STP TR repeater NMM
	m3333(41),		-- ethernet retiming module AUI
	m3334-ST(42),		-- ethernet retiming module FOIRL
	m3040(43),		-- model 3040 NCE (SPARCStation on a card)
	m3100R(44),		-- 3100R Summing Module
	notUsed45(45),		-- not assigned
	notUsed46(46),		-- not assigned
	m2810-hm(47),		-- host part of 2810 non-modular Ethernet
	m2810-nmm(48),		-- nmm part of 2810 non-modular Ethernet
	m3313S(49),		-- Ethernet NMM+ with AUI
	m3314S(50),		-- Ethernet NMM+ with FOIRL
	m3368(51),		-- 10Base-T LattisSecure Host Module
	m3512S(52),		-- Model 3512S Token Ring NMM
	m3513S(53),		-- Model 3513S Token Ring NMM
	m3514S(54),		-- Model 3514S Token Ring NMM
	m3522(55),		-- Model 3522 Token Ring bridge
	m2912(56),		-- FDDI STP workgroup concentrator
	m2914(57),		-- FDDI Fiber workgroup concentrator
	notUsed58(58),		-- not assigned
	m3301-75(59),		-- Thin net Enet Host Module for 75 ohms
	m3301-93(60),		-- Thin net Enet Host Module for 93 ohms
	m271x-nmm(61),		-- nmm part of 271x
	m2705-hm(62),		-- host connection to 2705
	m2715-hm(63),		-- host part of 2715
	m2813-nmm(64),		-- nmm part of 2813
	m2814-nmm(65),		-- nmm part of 2814
	m2813-hm(66),		-- host part of 2813
	m2814-hm(67),		-- host part of 2814
	m2803-hm(68),		-- cascaded 2803
	m2804-hm(69),		-- cascaded 2804
	m3395A(70),		-- Xyplex terminal server
	m3040S(71),		-- NCE (SPARCStation on a card)
	m3502B(72),		-- Model 3502B Token Ring Host Module
	m3505B(73),		-- Model 3505B Token Ring Host Module
	m2715-F-hm(74),		-- host part of 2715-F
	m2712-hm(75),		-- host part of 2712
	m2712-F-hm(76),		-- host part of 2712-F
	m2702-hm(77),		-- host connection to 2702
	m2702-C-hm(78),		-- host connection to 2702-C
	m2705-F-hm(79),		-- host connection to 2705-F
	m2702-F-hm(80),		-- host connection to 2702-F
	m2705-C-hm(81),		-- host connection to 2705-C
	m3902A(82),		-- Model 3902A FDDI host module
	m2912A(83),		-- FDDI SDDI workgroup concentrator
	m3313A(84),		-- Model 3313A Ethernet NMM
	m3314A(85),		-- Model 3314A Ethernet NMM
	m3307HD(86),		-- Model 3307HD Ethernet host module
	m3328(87),		-- Model 3328 Ethernet Switching Engine
	m3904-2SM(88),		-- Model 3904SM FDDI host module
	m3910S-SM(89),		-- Model 3910SM FDDI NMM
	m3800(90),		-- Cisco multi Media Router
	m3910S-SD(91),		-- Model 3910S-SD FDDI SDDI NMM
	m3904-4SM(92),		-- Model 3904-4SM FDDI single mode fiber host
	m2915(93),		-- Model 2915 FDDI UTP workgroup concentrator
	m3910SA(94),		-- Model 3910SA FDDI NMM II
	m3910SA-SM(95),		-- Model 3910SA FDDI NMM II with single mode fiber
	m3905(96),		-- Model 3905 FDDI UTP Host Module
	m2715B-hm(97),		-- host part of 2715B
	m2705B-hm(98),		-- host connection to 2705B
	m2715B-F-hm(99),	-- host part of 2715B-F
	m2712B-hm(100),		-- host part of  2712B
	m2712B-F-hm(101),	-- host part of 2712B-F
	m2702B-C-hm(102),	-- host connection to 2702B-C
	m3304A(103),		-- Redundant Ethernet Host Module
	m3486(104),		-- Model 3486 Lattis Engine / 486
	m3308B(105),		-- Model 3308B 10BASE-T Host Module
	m2813SA-nmm(106),	-- nmm part of 2813SA
	m2814SA-nmm(107),	-- nmm part of 2814SA
	m3517SA(108),		-- Model 3517SA Token Ring NMM
	m810M(109),		-- Model 810M eight port 10BASE-T Hub
	m3313SA(110),		-- Model 3313SA Ethernet NMM
	m3314SA(111),		-- Model 3314SA Ethernet NMM
	m3522A(112),		-- Model 3522A Token Ring Bridge
	m3504-ST(113),		-- Model 3504-ST Token Ring Host
	m3513SA(114),		-- Model 3513SA Token Ring NMM
	mAlcatel-Eth-nmm(115),	-- nmm part of Alcatel Ethernet workgroup conc.
	mAlcatel-Eth-hm1(116),	-- host part of Alcatel Ethernet workgroup conc.
	mAlcatel-Eth-hm(117),	-- cascaded Alcatel Ethernet workgroup conc.
	m2486-nmm(118),		-- nmm part of 2486
	m2486-hm(119),		-- host part of 2486
	m3174(120),		-- Model 3174 Communications Controller Module
	m271xSA-nmm(121),	-- nmm part of 271xSA
	m3299C(122),		-- Model 3299-C Terminal Multiplexor Adapter Module
	m3299U(123),		-- Model 3299-U TTP Terminal Multiplexor Adapter Module
	m3299F(124),		-- Model 3299-F Fiber Optic Terminal Adapter Module
	m2300x(125),		-- Model 2300x
	m2310x(126),		-- Model 2310x
        m3410(127),             -- Model 3410 Fast Ethernet Network Management Module
        m3405(128),             -- Model 3405 Fast Ethernet Host Module with 
                                -- 12 100BASE-TX ports
        m3475(129)              -- Model 3475 Fast Ethernet Host Module with 
                                -- 11 100BASE-TX ports and 1 100BASE-FX port

	}
-- This type is used to specify a module.


S3PsType ::= INTEGER {
	other(1),		-- none of the following
	low(2),			-- 200 watt supply (3000)
				-- 50 watt supply (281x)
	medium(3),		-- 360 watt supply (3000)
				-- 110 watt supply (3030)
				-- 85 watt supply (2715)
				-- 33 wattt supply (2300x & 2310x)
	high(4),		-- 460 watt supply (3000)
				-- 150 watt supply (3030)
				-- 150 watt supply (2914 & 2912)
	redundantCapable(5),	-- redundant backplane (3000)
	empty(6)		-- nothing installed
	}
-- This type is used to specify the power supply type. Where used,
--   the descriptions specify the valid values.

-- Groups

s3AgentSw		OBJECT IDENTIFIER ::= { s3SnmpAgent 1 }
s3AgentNetProtocol	OBJECT IDENTIFIER ::= { s3SnmpAgent 2 }
s3AgentIpProtocol	OBJECT IDENTIFIER ::= { s3AgentNetProtocol 1 }
-- this one is defined in the IPX MIB
-- s3AgentIpxProtocol	OBJECT IDENTIFIER ::= { s3AgentNetProtocol 2 }
-- this one is defined in section 3.
-- s3AgentTrapReceiverTable	OBJECT IDENTIFIER ::= { s3SnmpAgent 3 }
s3AgentHw		OBJECT IDENTIFIER ::= { s3SnmpAgent 4 }
s3AgentSpecific		OBJECT IDENTIFIER ::= { s3SnmpAgent 5 }
s3AgentLocImage		OBJECT IDENTIFIER ::= { s3SnmpAgent 6 }
-- this one is defined in the IPX MIB
-- s3AgentIPXTrapReceiverTable	OBJECT IDENTIFIER ::= { s3SnmpAgent 7 }

s3000Chassis		OBJECT IDENTIFIER ::= { series3000 1 }
s3000RedundantPs	OBJECT IDENTIFIER ::= { s3000Chassis 10 }
s3000Ethernet		OBJECT IDENTIFIER ::= { series3000 2 }
s3000TokenRing		OBJECT IDENTIFIER ::= { series3000 3 }
s3000FDDI		OBJECT IDENTIFIER ::= { series3000 4 }
s3000Bridge		OBJECT IDENTIFIER ::= { series3000 5 }
s3000TerminalServer	OBJECT IDENTIFIER ::= { series3000 6 }
s3000LattisTalk		OBJECT IDENTIFIER ::= { series3000 7 }
s3000Trb		OBJECT IDENTIFIER ::= { series3000 8 }



-- SECTION 2: Concentrator Chassis

-- Chassis Group


-- Implementation of this group is mandatory for all SynOptics
--   Series 3000 agents


s3ChassisType OBJECT-TYPE
	SYNTAX	SnpxChassisType
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis type."
	::= { s3000Chassis 1 }

s3ChassisBkplType OBJECT-TYPE
	SYNTAX	SnpxBackplaneType
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis backplane type."
	::= { s3000Chassis 2 }

s3ChassisBkplRev OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis backplane revision."
	::= { s3000Chassis 3 }

s3ChassisPsType OBJECT-TYPE
	SYNTAX	S3PsType
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis power supply type.  This value is
		valid only when the backplane type is not
		other(1).  If the chassis has a redundant backplane,
		the agent returns redundantCapable(5), even if only
		one power supply is installed.  The objects
		s3RedPsPrimaryConfig and s3RedPsSecondaryConfig
		should be consulted to determine the installed
		power supply type(s) with redundant backplanes."
	::= { s3000Chassis 4 }

s3ChassisPsStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		ok(1),			-- supply ok
		primaryFail(2),		-- primary power supply failure
		secondaryFail(3),	-- secondary power supply failure
		bothFail(4)		-- both power supplies failed
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis power supply status."
	::= { s3000Chassis 5 }

s3ChassisFanStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		ok(1),			-- fans are running
		fail(2),		-- fan(s) are broken
		other(3)		-- unknown fan status or no fan
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The status of the chassis cooling fan."
	::= { s3000Chassis 6 }



-- Chassis Slot Configuration Table


s3SlotConfigTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF S3SlotConfigEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"The chassis slot configuration table."
	::= { s3000Chassis 7 }

s3SlotConfigEntry OBJECT-TYPE
	SYNTAX	S3SlotConfigEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"What type of module is in each slot of the chassis."
	INDEX	{ s3SlotNumber }
	::= { s3SlotConfigTable 1 }


S3SlotConfigEntry ::= SEQUENCE {
	s3SlotNumber
		INTEGER,
	s3SlotModuleId
		INTEGER,
	s3SlotModuleType
		S3ModuleType,
	s3SlotModuleDescr
		DisplayString,
	s3SlotModuleLed
		OCTET STRING,
	s3SlotModuleMdaId
		INTEGER
	}

s3SlotNumber OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The 3000 Chassis slot number. Valid entries are 1-12."
	::= { s3SlotConfigEntry 1 }

s3SlotModuleId OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"ID for the module.  Values are specified in
		SynOptics technical documents."
	::= { s3SlotConfigEntry 2 }

s3SlotModuleType OBJECT-TYPE
	SYNTAX	S3ModuleType
	ACCESS	read-only
	STATUS	deprecated
	DESCRIPTION
		"The type of module this entry represents.
		Values are specified in SynOptics technical documents."
	::= { s3SlotConfigEntry 3 }

s3SlotModuleDescr OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(0..128))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Module description.  Values are specified in
		SynOptics technical documents."
	::= { s3SlotConfigEntry 4 }

s3SlotModuleLed OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(8))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Status of the module LEDs.  Format is specified in
		SynOptics technical documents.  NOTE: the 291x FDDI
		workgroup concentrators actually return a string
		with size of 10."
	::= { s3SlotConfigEntry 5 }

s3SlotModuleMdaId OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"ID of the medium-dependent part of the board.
		The value is board dependent. Values are specified
		in SynOptics technical documents."
	::= { s3SlotConfigEntry 6 }



-- Chassis Common Board Table


s3CommonBoardTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF S3CommonBoardEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A table containing information about the boards
		currently plugged into the 3000 Chassis.  This
		board table contains an entry for each non-empty
		slot in the s3SlotConfigTable, EXCEPT for those
		slots containing Retiming Modules.

		All of the information in this board table is
		retrievable using the NMI commands that are common
		to all boards integrated into the SynOptics
		Series 3000 Concentrators."
	::= { s3000Chassis 8 }

s3CommonBoardEntry OBJECT-TYPE
	SYNTAX	S3CommonBoardEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A table entry containing information about a
		single Board currently plugged into the 3000
		Chassis. These values can be retrieved using the
		common board NMI commands."
	INDEX	{ s3CommonBoardIndex }
	::= { s3CommonBoardTable 1 }

S3CommonBoardEntry ::= SEQUENCE {
	s3CommonBoardIndex
		INTEGER,
	s3CommonBoardId
		INTEGER,
	s3CommonBoardHwVer
		INTEGER,
	s3CommonBoardStatus
		INTEGER,
	s3CommonBoardReset
		INTEGER,
	s3CommonBoardPartStatus
		INTEGER,
	s3CommonBoardNmCntlStatus
		INTEGER,
	s3CommonBoardPsStatus
		INTEGER,
	s3CommonBoardPartTime
		TimeTicks
	}

s3CommonBoardIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"A unique value for each board. Its value ranges
		between 1 and 12. The value for each board must
		remain constant at least from one re-initialization
		of the entity's network management system to the
		next re-initialization."
	::= { s3CommonBoardEntry 1 }

s3CommonBoardId OBJECT-TYPE
	SYNTAX  INTEGER {
	m331x(1),
	m3302(2),
	m332x(3),
	m3304ST(4),
	m3305(5),
	m333x(6),
	m3307(7),
	m3308(8),
	m3301(9),
	m3904(10),
	m3902(11),
	m3910S(12),
--	mNotAssigned13(13),
	m331xS(14),
	m3100R(15),
	m3502(16),
	m3502A(17),
	m353x(18),
	m3040(19),
	m3505(20),
	m3505A(21),
	m355x(22),
	m3040S(23),
	m351x(24),
	m332xS(25),
	m338x(26),
	m3328(27),
	m3395(28),
	m3394(29),
	m3522(30),
	m3395A(31),
	m3800(32),
--	mNotAssigned33(33),
--	mNotAssigned34(34),
--	mNotAssigned35(35),
	m3368(36),
--	mNotAssigned37(37),
	m3308A(38),
	m2810nmm(39),
	m2810hm(40),
	m3301ohms75(41),
	m3301ohms93(42),
	m2912(43),
	m2914(44),
	m3502B(45),
	m3505B(46),
	m3307HD(47),
	m2702Fhm(48),
	m2712Fhm(49),
	m2712hm(50),
	m2702hm(51),
	m2813nmm(52),
	m2813hm(53),
	m2814hm(54),
	m2803hm(55),
	m3356(56),
	m2814nmm(57),
	m2804hm(58),
	m2702Chm(59),
	m2715Fhm(60),
	m2705Fhm(61),
	m2705Chm(62),
	m3902A(63),
	m2912A(64),
	m271xnmm(65),
	m2715hm(66),
	m3910SSD(67),
	m3313A(68),
	m3314A(69),
	m3304A(70),
	m3910SA(71),
	m2705hm(72),
	m3905(73),
	m2915(74),
	m2715Bhm(75),
	m2705Bhm(76),
	m2715BFhm(77),
	m2712Bhm(78),
	m2712BFhm(79),
	m2702BChm(80),
--	mNotAssigned81(81),
	m3486(82),
--	mNotAssigned83(83),
--	mNotAssigned84(84),
--	mNotAssigned85(85),
--	mNotAssigned86(86),
--	mNotAssigned87(87),
	m810m(88),
--	mNotAssigned89(89),
--	mNotAssigned90(90),
--	mNotAssigned91(91),
--	mNotAssigned92(92),
--	mNotAssigned93(93),
--	mNotAssigned94(94),
--	mNotAssigned95(95),
--	mNotAssigned96(96),
--	mNotAssigned97(97),
--	mNotAssigned98(98),
--	mNotAssigned99(99),
--	mNotAssigned100(100),
	m3517SA(101),
	m3308B(102),
	m2813SAnmm(103),
	m2814SAnmm(104),
	m3313SA(105),
	m3314SA(106),
	m3174(107),
	m3522A(108),
	m3513SA(109),
	m271xSAnmm(110),
	m2300x(114), 
	m2310x(115),
	m3299C(116),
	m3299U(117),
	m3299F(119),
        m3410(120),
        m3405(121),
        m3475(122),
	mAlcatelEthConcnmm(250),
	mAlcatelEthConchm(251),
	mAlcatelEthExpConchm(252)
	}
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
	"This is the ID of the board, which is 'hard-coded' in the
	board, and identifies the board's basic functionality.
	Some boards have the capability to change aspects of
	their functionality, such as media type, interface types,
	or power supply wattages, by plugging in different daughter
	cards.  Other boards may identify the type of cable plugged
	into them.  The boards that have these capabilities use 
	different values for the object s3SlotModuleMda to identify
	the changable portion of the functionality currently used.
	Boards that do not support these capabilities typically set
	the object s3SlotModuleMda to 255 or zero.  The combination
	of the value of this object and the s3SlotModuleMda object
	are then mapped by software to determine the type of
	module (i.e., s3SlotModuleType).

	Notes:  1.)  The object s3SlotModuleType is marked
	             as deprecated.
	        2.)  Agents do not implement a complete mapping of
	             s3CommonBoardId and s3SlotModuleMda to
	             s3SlotModuleType.  The mapping that is performed
	             pertains to the media type of the agent.

	The possible values for this object are:
	  m331x(1)...................331x Ethernet NMM
	  m3302(2)...................3302 Ethernet STP Host
	  m332x(3)...................332x Ethernet Local Bridge
	  m3304ST(4).................3304 Ethernet FOIRL-ST Host
	  m3305(5)...................3305 Ethernet UTP Host
	  m333x(6)...................333x Ethernet Repeater/Retiming
	  m3307(7)...................3307 Ethernet 50 Pin UTP Host
	  m3308(8)...................3308 10BaseT UTP Host
	  m3301(9)...................3301 10Base2 Thin Net Host
	  m3904(10)..................3904 FDDI Multimode Fiber Host
	  m3902(11)..................3902 FDDI STP Host
	  m3910S(12).................3910S FDDI NMM
	  m331xS(14).................331xS Ethernet NMM
	  m3100R(15).................3100R Power Supply Summing
	  m3502(16)..................3502 Token Ring Passive STP Host
	  m3502A(17).................3502A Token Ring Passive STP/UTP Host
	  m353x(18)..................353x Token Ring RI/RO Repeater
	  m3040(19)..................3040 Network Control Engine (NCE)
	  m3505(20)..................3505 Token Ring Active UTP Host
	  m3505A(21).................3505A Token Ring Active UTP Host
	  m355x(22)..................355x Token Ring FOIRL RI/RO Repeater
	  m3040S(23).................3040S Network Control Engine
	  m351x(24)..................351x Token Ring NMM
	  m332xS(25).................332xS Ethernet High Speed Local Bridge
	  m338x(26)..................338x Ethernet Remote Router
	  m3328(27)..................3328 Ethernet Switching Engine (ESE)
	  m3395(28)..................3395 Terminal Server
	  m3394(29)..................3394 LattisTalk Router/Repeater
	  m3522(30)..................3522 Token Ring Local Bridge
	  m3395A(31).................3395A Terminal Server
	  m3800(32)..................3800 Multimedia Router
	  m3368(36)..................3368 Ethernet LattisSecure Host
	  m3308A(38).................3308A 10BaseT Host
	  m2810nmm(39)...............2810 Ethernet NMM
	  m2810hm(40)................2810 Ethernet Host
	  m3301ohms75(41)............3301-75 Ethernet Thin Net Host (75-ohm)
	  m3301ohms93(42)............3301-93 Ethernet Thin Net Host (93-ohm)
	  m2912(43)..................2912 FDDI STP Concentrator
	  m2914(44)..................2914 FDDI Fiber Concentrator
	  m3502B(45).................3502B Token Ring Passive STP/UTP Host
	  m3505B(46).................3505B Token Ring Active STP/UTP Host
	  m3307HD(47)................3307HD Ethernet 100 Pin UTP Host
	  m2702Fhm(48)...............2702F Token Ring Passive Host
	  m2712Fhm(49)...............2712F Token Ring Passive Host
	  m2712hm(50)................2712 Token Ring Passive Host
	  m2702hm(51)................2702 Token Ring Passive Host
	  m2813nmm(52)...............2813 Ethernet NMM
	  m2813hm(53)................2813 Ethernet Host
	  m2814hm(54)................2814 Ethernet Host
	  m2803hm(55)................2803 Ethernet Host
	  m3356(56)..................3356 Ethernet Remote Bridge
	  m2814nmm(57)...............2814 Ethernet NMM
	  m2804hm(58)................2804 Ethernet Host
	  m2702Chm(59)...............2702C Token Ring Passive Host
	  m2715Fhm(60)...............2715F Token Ring Active Host
	  m2705Fhm(61)...............2705F Token Ring Active Host
	  m2705Chm(62)...............2705C Token Ring Active Host
	  m3902A(63).................3902A FDDI STP Host
	  m2912A(64).................2912A FDDI STP Concentrator
	  m271xnmm(65)...............271x Token Ring NMM
	  m2715hm(66)................2715 Token Ring Active Host
	  m3910SSD(67)...............3910S-SD FDDI NMM
	  m3313A(68).................3313A Ethernet NMM
	  m3314A(69).................3314A Ethernet NMM
	  m3304A(70).................3304A Ethernet 10BaseF Host
	  m3910SA(71)................3910SA FDDI NMM
	  m2705hm(72)................2705 Token Ring Active Host
	  m3905(73)..................3905 FDDI UTP Host
	  m2915(74)..................2915 FDDI UTP Concentrator
	  m2715Bhm(75)...............2715B Token Ring Active Host
	  m2705Bhm(76)...............2505B Token Ring Active Host
	  m2715BFhm(77)..............2715B-F Token Ring Active Host
	  m2712Bhm(78)...............2712B Token Ring Passive Host
	  m2712BFhm(79)..............2712B-F Token Ring Passive Host
	  m2702BChm(80)..............2702B-C Token Ring Passive Host
	  m3486(82)..................3486 LattisEngine/486
	  m810m(88)..................810M Ethernet Concentrator
	  m3517SA(101)...............3517SA Token Ring NMM
	  m3308B(102)................3308B 10BaseT Host
	  m2813SAnmm(103)............2813SA Ethernet NMM
	  m2814SAnmm(104)............2814SA Ethernet NMM
	  m3313SA(105)...............3313SA Ethernet NMM
	  m3314SA(106)...............3314SA Ethernet NMM
	  m3174(107).................3174 Workstation Controller
	  m3522A(108)................3522A Token Ring Local Bridge
	  m3513SA(109)...............3513SA Token Ring NMM
	  m271xSAnmm(110)............271xSA Token Ring NMM
	  m2300x(114)................2300x Product
	  m2310x(115)................2310x Product
	  m3299C(116)................3299-C Terminal Multiplexor Adapter
	  m3299U(117)................3299-U TTP Terminal Multiplexor Adapter
	  m3299F(119)................3299-F Fiber Optic Terminal Adapter
          m3410(120).................3410 Fast Ethernet Network
                                     Management Module
          m3405(121).................3405 Fast Ethernet Host Module with
                                     12 100BASE-TX ports
          m3475(122).................3475 Fast Ethernet Host Module with
                                     11 100BASE-TX ports and 1 100BASE-FX port

	  mAlcatelEthConcnmm(250)....Alcatel Ethernet NMM
	  mAlcatelEthConchm(251).....Alcatel Ethernet Host
	  mAlcatelEthExpConchm(252)..Alcatel Ethernet Expansion Host"
	::= { s3CommonBoardEntry 2 }

s3CommonBoardHwVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The hardware revision of the board.
		  0=Rev. A, 1=Rev. B, etc."
	::= { s3CommonBoardEntry 3 }

s3CommonBoardStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		ok(1),			-- good status
		fail(2)			-- bad status
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates the operational status of the board."
	::= { s3CommonBoardEntry 4 }

s3CommonBoardReset OBJECT-TYPE
	SYNTAX	INTEGER {
		noReset(1),		-- not resetting
		reset(2)		-- resetting
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This indicates the reset state of the board.
		Writing with the value reset (2) will reset
		the board."
	::= { s3CommonBoardEntry 5 }

s3CommonBoardPartStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		enabled(1),		-- board enabled
		partition(2),		-- board partitioned indefinitely
		timedPartition(3)	-- board partitioned for a
					--   time period
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Tells whether the board is partitioned or enabled.
		Writing with the value partition(2) will partition
		the board indefinitely and writing with the value
		enabled(1) will enable the board.

		If a timed partition is desired, then this object
		must be written with timedPartition(3) and in the
		same PDU a partition duration must be supplied in
		s3CommonBoardPartTime. Timed partitions will not
		survive across a reset. In this case the port will
		go to the partition(2) state.

		Boards cannot be partitioned in the 2810 concentrator
		and other workgroup concentrators. These agents will
		implement this object as read-only."
	::= { s3CommonBoardEntry 6 }

s3CommonBoardNmCntlStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		notNmControl(1),	-- board not under NM control
		nmControl(2)		-- board under NM control
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Tells whether the board is under network management
		control.  The value nmControl(2) indicates that the
		board or one or more ports are being controlled by
		network management.  This means that the board
		or one or more ports are partitioned via a network
		manager."
	::= { s3CommonBoardEntry 7 }

s3CommonBoardPsStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		ok(1),			-- good status
		fail(2)			-- bad status
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates the operational status of the board
		power supply.  A fail(2) indicates that one of the
		power supplies on the board has failed."
	::= { s3CommonBoardEntry 8 }

s3CommonBoardPartTime OBJECT-TYPE
	SYNTAX	TimeTicks
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"When partitioning the board for a specified time, 
		s3CommonBoardPartStatus must be set with
		timedPartition(3) and this object must be supplied
		with the duration value. If a PDU sets 
		s3CommonBoardPartStatus and not this object, the
		board will not be partitioned.  This value is
		decremented while the board is partitioned
		until the value reaches zero at which time the
		board is enabled."
	::= { s3CommonBoardEntry 9 }


-- Packed Slot Configuration Table


s3SlotConfigOctetString OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(12..144))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Packed octet string for the slot configuration table.
		Format is specified in SynOptics technical documents.
		NOTE: the 291x FDDI workgroup concentrators actually
		return a string with size a multiple of 14."
	::= { s3000Chassis 9 }



-- Redundant Power Supply Group


-- Support of the entire Redundant Power Supply group is mandatory
--   for every SynOptics 4.1 agent in a chassis with redundant
--   backplane.  (These are the agents that return the value
--   redundantCapable(5) for s3ChassisPsType. Note: this does not
--   include the FDDI 4.0 agents.)


s3RedPsPlus5vCurrent OBJECT-TYPE
	SYNTAX	Gauge
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This gauge is measured in amperes."
	 ::={ s3000RedundantPs 1 }

s3RedPsPlus12vCurrent OBJECT-TYPE
	SYNTAX	Gauge
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This gauge is measured in amperes."
	::={ s3000RedundantPs 2 }

s3RedPsAmbientTempStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),
		normalTemperature(2),
		aboveNormalTemp(3)
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This status indicates whether the ambient
		temperature is  normal, i.e., below 40 degree C."
	 ::={ s3000RedundantPs 3 }

s3RedPsAmbientTemperature OBJECT-TYPE
	SYNTAX	Gauge
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This gauge is measured in Celsius."
	::={ s3000RedundantPs 4 }

s3RedPsPrimaryConfig OBJECT-TYPE
	SYNTAX	S3PsType
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates the primary power supply type
		(PS 1).  Note that value redundantCapable(5)
		should not be returned for this object."
	::={ s3000RedundantPs 5 }

s3RedPsSecondaryConfig OBJECT-TYPE
	SYNTAX	S3PsType
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates the secondary power supply type
		(PS 2).  Note that value redundantCapable(5)
		should not be returned for this object."
	 ::={ s3000RedundantPs 6 }

s3RedPsDiodeStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),		-- not applicable
		bothOk(2),		-- both diodes ok
		primaryFail(3),		-- primary diode fail
		secondaryFail(4),	-- secondary diode fail
		bothFail(5)		-- both diode fail
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This gives the status of the summing diode on the
		3100R associated with the indicated power supply."
	 ::={ s3000RedundantPs 7 }

s3RedPsPowerAlarm OBJECT-TYPE
	SYNTAX	INTEGER	{
		other(1),		-- not applicable
		bothOk(2),		-- both power supplies ok
		primaryFail(3),		-- primary supply fail
		secondaryFail(4),	-- secondary supply fail
		bothFail(5)		-- both supplies fail
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This tells whether the indicated power supply is
		sensing voltage on the backplane."
	 ::={ s3000RedundantPs 8 }



-- Channel Divider Information

s3ChassisBkPlEthChanDiv OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"A value that describes the divisions of the
		segmentable ethernet channel.  For those devices
		that do not implement a backplane with this feature,
		they still need to implement this object and return
		a value (i.e., zero) to indicate that no divisions
		are enabled.

		The value is a sum (i.e., integer bit string).
		This value initially takes the value of zero,
		then for each division that is enabled on the channel,
		2 raised to a power is added to the sum.  The powers
		are according to the following table:

		  Division between    Power
		    Slots 4 and 5     0
		    Slots 6 and 7     1
		    Slots 8 and 9     2

		For example, a channel with no divisions enabled
		(i.e., not segmented) would have a value of 0.
		A channel with divisions between slots 6 and 7,
		and slots 8 and 9 enabled (i.e., having three
		segments) would have a value of 6 (2**1 + 2**2)."
	::= {  s3000Chassis 11 }


s3ChassisEnetChannelAType OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),	   -- unknown or no Ethernet
		aSegmentable(2),   -- Enet chan A is segmentable
		aNotSegmentable(3) -- Enet chan A is not segmentable
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The agent will return aSegmentable(2) for the 3000N,
		3000NT, 3000S, 3000SR, and any other backplanes in
		which Ethernet channel A can be divided into multiple
		segments.  The value aNotSegmentable(3) indicates
		that the Ethernet backplane channel A cannot be
		segmented.

		For Token Ring or FDDI workgroup concentrators, or
		other devices in which there is no Ethernet channel,
		the agent will return other(1)."
	::= {  s3000Chassis 12 }



-- SECTION 3: Agent Configuration

-- Agent Software Group


-- Implementation of this group is mandatory for all SynOptics
--   Series 3000 agents


s3AgentType OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),	-- none of the following
		m3313(2),	-- AUI Ethernet NMM w/ RS232 port
				--  (may also be returned by a 2810)
		m3313M(3),	-- AUI Enet NMM w/ RS232 port + modem
		m3314-ST(4),	-- FOIRL Ethernet NMM w/ RS232
		m3314M-ST(5),	-- FOIRL Ethernet NMM w/ RS232 + modem
		m2310(6),	-- Model 2310
		m3512(7),	-- T.R. NMM w/ STP ring in/ring out
		m3514(8),	-- T.R. NMM w/ FOIRL ring in/ring out
		m332x(9),	-- Low Speed Local Bridge
		m3356(10),	-- Ethernet Remote Bridge
		m332xS(11),	-- High Speed Local Bridge
		m3910S(12),	-- FDDI Super NMM
		m3395(13),	-- terminal server
		m3394(14),	-- Ethernet-localtalk router
		m3513(15),	-- TR NMM with STP repeater
		m331xS(16),	-- Ethernet NMM+
		m291x(17),	-- FDDI 291x workgroup concentrator
		m271x(18),	-- T.R. 271x workgroup concentrator
		m281x(19),	-- Ethernet 281x workgroup concentrator
		m331xA(20),	-- Ethernet 331xA NMM
		m3522(21),	-- Token Ring Local Bridge Module
		m2722(22),	-- Standalone Token Ring Local Bridge
		m281xSA(23),	-- Ethernet 281xSA workgroup concentator
		m810M(24),	-- Ethernet LattisHub 810M NMM
		m351xSA(25),	-- T.R. 351xSA NMM
		m331xSA(26),	-- Ethernet 331xSA NMM
		m271xSA(27),	-- T.R. 271xSA workgroup concentrator
		m2486(28),	-- LattisEngine 2486
		m2300x(29),	-- 2300x product
		m2310x(30)	-- 2310x product
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The 3000 series agent's Module type."
	::= {s3AgentSw  1 }

s3AgentFwVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The agent's module firmware version
		0=Rev A,1=Rev B,etc."
	::= { s3AgentSw 2 }

s3AgentSwMajorVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The agent major software version number.
		(version is specified as major.minor.maint or 3.0.1).
		Object is in decimal."
	::= { s3AgentSw 3 }

s3AgentSwMinorVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The agent minor software version number
		(version is specified as major.minor.maint or 3.0.1).
		Object is in decimal."
	::= { s3AgentSw 4 }

-- NOTE: the maintenance object, s3AgentSwMaintVer, is defined below.

s3AgentBootProtocol OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),	-- boot protocol not listed here
		bootp-tftp(2),
		tftp-only(3),
		ieee802-1e(4),
		proprietary(5),	-- supported proprietary boot protocol
		dll-download(6)	-- direct async binary download (Retix)
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Boot protocol used to load the module with its software.
		On Agents with the Local Load option the value return by
		this object is valid only if the MIB object
		s3LocImageLoadMode is remoteBoot(2) or localAsBackup(4)."
	::= {s3AgentSw 5 }

s3AgentBootFile OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(0..64))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The name of the boot file that is sent to the file
		server during boot time.  The actual boot protocol
		used to retrieve the file is determined by 
		s3AgentBootProtocol.

		This parameter will not take effect until written 
		into EEPROM (s3AgentWriteEeprom) and a reset
		(s3AgentReset) is issued. This parameter is used
		only if the s3AgentBootMode is set to use EEPROM."
	::= { s3AgentSw 6 }

s3AgentAuthTrap OBJECT-TYPE
	SYNTAX	INTEGER {
		disable(1),		-- disable authentication traps
		enable(2)		-- enable authentication traps
		}
	ACCESS	read-write
	STATUS	deprecated
	DESCRIPTION
		"Enable or disable the use of authentication error
		trap generation.

		This parameter will take effect only after a restart
		(s3AgentRestart) is issued.  This parameter will not
		survive a reset (s3AgentReset) unless the specific
		NMM configuration file is updated to reflect the
		change.

		This object is now deprecated.  Managers should use
		the snmpEnableAuthenTraps object in MIB-II instead.
		This object is aliased to snmpEnableAuthenTraps.
		Changing either variable will change the other
		accordingly."
	::= { s3AgentSw 7 }

s3AgentLocation OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(0..64))
	ACCESS	read-write
	STATUS	deprecated
	DESCRIPTION
		"This is a informational string that could be used
		to show the physical location (i.e. area) of the
		NMM or concentrator.

		This parameter will take effect only after a restart
		(s3AgentRestart) is issued.  This parameter will not
		survive a reset (s3AgentReset) unless the specific
		NMM configuration file is updated to reflect the
		change.

		This object is now deprecated.  Managers should use
		the sysLocation object in MIB-II instead."
	::= { s3AgentSw 8 }

s3AgentMibLevel OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Used to determine current MIB release supported
		by agent.  The encoding of this object is of the
		following form: xyy, where x is the major version
		number and yy is the minor version number.  Thus,
		version 3.0 would be represented as 300,  version
		3.01 would be 301 and 3.1 would be 310.  Object is
		in decimal.  Values that correspond to each agent
		type and version are specified in the other
		SynOptics documentation."
	::= { s3AgentSw 9 }

s3AgentFeatureLevel OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	deprecated
	DESCRIPTION
		"Used to determine feature level of the agent.
		The encoding of this object is of the following
		form: xyy, where x is the major version 
		number and yy is the minor version number.  Thus,
		feature level version 1.0 would be represented as
		100, version 1.01 would be 101 and 1.1 would be 110.
		Object is in decimal. The current values are the
		following:
		  100 - 331x V3.x
		        - Basic Agent
		  100 - 351x
		        - Basic Agent
		  100 - 271x V3.x
		        - Basic Agent
		  101 - 281x V5.0 
		        - Basic Agent
		        - Dual Stack
		  102 - 331x V4.2.0
		        - Basic Agent
		        - Non Segmentable Chassis
		        - Ethernet Common board table
		        - Ethernet Command port table
		        - redundant power supply group
		  103 - 331xA V4.2.0
		        - Basic Agent
		        - Segmentable chassis
		        - Ethernet Common board table
		        - Ethernet Common port table
		        - redundant power supply group
		        - Ethernet plus statistics,
		  104 - 331xA V4.2.0
		        - Basic Agent
		        - Non-Segmentable chassis
		        - Ethernet Common board table
		        - Ethernet Common port table
		        - redundant power supply group
		        - Ethernet plus statistics,
		  109 - 331x V4.2.0
		        - Basic Agent
		        - Segmentable Chassis
		        - Ethernet Common board table
		        - Ethernet Common port table
		        - redundant power supply group
		  112 - 281x V5.1.0
		        - Basic Agent
		        - Dual Stack
		        - Network to MAC address mapping
		  113 - 331x V5.1.0
		        - Basic Agent
		        - Segmentable chassis
		        - Full Truffle Support
		        - Dual Stack
		        - Network to MAC address mapping
		  114 - 331x V5.1.0
		        - Basic Agent
		        - Non-Segmentable chassis
		        - Full Truffle Support
		        - Dual Stack
		        - Network to MAC address mapping
		  115 - 331xA V5.1.0
		        - Basic Agent
		        - Segmentable chassis
		        - Dual Stack
		        - Full Truffle Support
		        - Network to MAC address mapping
		  116 - 331xA V5.1.0
		        - Basic Agent
		        - Non-Segmentable chassis
		        - Dual Stack
		        - Full Truffle Support
		        - Network to MAC address mapping
		  200 - 331x V4.0 & V4.0.1
		        - Advanced Agent
		  200 - 271x V4.x
		        - Advanced Agent
		  200 - 351x V4.x
		        - Advanced Agent
		  200 - all FDDI Agents
		  201 - 331x V4.1.0, V4.1.1
		        - Advanced Agent
		        - redundant power supply group
		  202 - 331xS V4.1.0, V4.1.1
		        - Advanced Agent
		        - redundant power supply  group
		        - DS/SD traffic tables,
		        - Ethernet plus statistics,
		        - frame type distribution table
		        - frame length distribution table
		  203 - 281x V4.2.0
		        - Advanced Agent
		        - Dual Stack
		  204 - 331x V4.2.0
		        - Advanced Agent
		        - Non-Segmentable chassis
		        - Ethernet Common board table
		        - Ethernet Common port table
		        - redundant power supply group
		  205 - 331xS V4.2.0
		        - Advanced Agent
		        - Segmentable chassis
		        - Ethernet Common board table
		        - Ethernet Common port table
		        - redundant power supply  group
		        - DS/SD traffic tables,
		        - Ethernet plus statistics,
		        - frame type distribution table
		        - frame length distribution table
		  206 - 331xS V4.2.0
		        - Advanced Agent
		        - Non-Segmentable chassis
		        - Ethernet Common board table
		        - Ethernet Common port table
		        - redundant power supply  group
		        - DS/SD traffic tables,
		        - Ethernet plus statistics,
		        - frame type distribution table
		        - frame length distribution table
		  207 - 331xA V4.2.0
		        - Advanced agent
		        - Segmentable chassis
		        - Ethernet Common board table
		        - Ethernet Common port table
		        - redundant power supply  group
		        - Ethernet plus statistics,
		  208 - 331xA V4.2.0
		        - Advanced agent
		        - Non-Segmentable chassis
		        - Ethernet Common board table
		        - Ethernet Common port table
		        - redundant power supply  group
		        - Ethernet plus statistics,
		  209 - 331x V4.2.0
		        - Advanced agent
		        - Segmentable chassis
		        - Ethernet Common board table
		        - Ethernet Command port table
		        - redundant power supply group
		  212 - 331x V5.1.0
		        - Advanced Agent
		        - Dual Stack
		        - Network to MAC address mapping
		        - RMON Ether Stats, History, Alarm, Event Groups
		  213 - 281x V5.1.0
		        - Advanced Agent
		        - Segmentable chassis
		        - Full Truffle Support
		        - Dual Stack
		        - Network to MAC address mapping
		        - RMON Ether Stats, History, Alarm, Event Groups
		  214 - 331x V5.1.0
		        - Advanced Agent
		        - Non-Segmentable chassis
		        - Full Truffle Support
		        - Dual Stack
		        - Network to MAC address mapping
		        - RMON Ether Stats, History, Alarm, Event Groups
		  215 - 331xA V5.1.0
		        - Advanced Agent
		        - Segmentable chassis
		        - RMON Ether Stats, History, Alarm, Event Groups
		        - Dual Stack
		        - Full Truffle Support
		        - Network to MAC address mapping
		  216 - 331xA V5.1.0
		        - Advanced Agent
		        - Non-Segmentable chassis
		        - Full Truffle Support
		        - Dual Stack
		        - Network to MAC address mapping
		        - RMON Ether Stats, History, Alarm, Event Groups
		  217 - 331xS V5.1.0
		        - Advanced Agent
		        - Segmentable chassis
		        - Full Truffle Support
		        - Dual Stack
		        - Network to MAC address mapping
		        - RMON Ether Stats, History, Alarm, Event Groups
		        - Bulk table retrieval for traffic matrix
		  218 - 331xS V5.1.0
		        - Advanced Agent
		        - Non-Segmentable chassis
		        - Full Truffle Support
		        - Dual Stack
		        - Network to MAC address mapping
		        - RMON Ether Stats, History, Alarm, Event Groups
		        - Bulk table retrieval for traffic matrix"
	::= { s3AgentSw 10 }

s3AgentMySlotId OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Slot where this agent currently resides.  If
		hardware is unable to determine then a 0 should
		be returned."
	::= { s3AgentSw 11 }

s3AgentUnAuthIp OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This object contains the IP address of the last
		station that tried to access this agent with an
		invalid community string.  This object is used
		as a VarBind in an Authentication Trap PDU.  A get
		request will return the last value used, and will
		return the null address 0.0.0.0 if no 
		authentication traps have been sent."
	::= { s3AgentSw 12 }

s3AgentUnAuthComm OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(0..20))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This object contains the community string of the
		last unauthenticated attempt to access this agent.
		This object is used as a VarBind in an Authentication
		Trap PDU.  A get request will return the last value
		used, and will return the null string (length 0) if
		no authentication traps have been sent."
	::= { s3AgentSw 13 }

s3AgentSwLicenseCode OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(8))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The software license code assigned to this agent.
		This code is required for initializing the agent.
		The code consists of exactly eight printable
		characters."
	::= { s3AgentSw 14 }

s3AgentPerformance OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This counts the CPU idle time of the agent
		in units of 10 microseconds."
	::= { s3AgentSw 15 }

s3AgentSwMaintVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The agent software maintenance version number
		(version is specified as major.minor.maint or 3.0.1).
		Object is in decimal."
	::= { s3AgentSw 16 }

s3AgentConfigLoadMode OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),	 -- configuration source not listed here
		remoteConfig(2), -- use net, not local configuartion data
		localConfig(3),	 -- use local configuration data
		localAsBackup(4) -- try net, if fails use local
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the agent should get
		configuration data from the network, use the local
		configuration data, or try the network first and then
		fall back to local configuration if the network load
		fails.  This object applies only to agents with boot
		prom support for agent configuration load options.

		This parameter will not take effect until written into
		EEPROM (s3AgentWriteEeprom) and a reset (s3AgentReset)
		is issued."
	::= { s3AgentSw 17 }

s3AgentConfigActualSource OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),
		remoteConfig(2),
		localConfig(3)
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the agent loaded configuration
		data from the network or used the local configuration
		data."
	::= { s3AgentSw 18 }

s3AgentMgmtProtoMode OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),	-- unknown or other
		ip(2),		-- IP only, all IPX packets will be dropped
		ipx(3),		-- IPX only, all IP packets will be dropped
		ipAndIpx(4) 	-- both IP and IPX packets will be accepted
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This indicates from which network transports over
		which the agent will accept SNMP requests.  This object
		only applies to agents with IP and IPX dual stack support.

		This parameter will not take effect until written into
		EEPROM (s3AgentWriteEeprom) and a reset (s3AgentReset)
		or a restart (s3AgentRestart) is issued."
	::= { s3AgentSw 19 }

s3AgentActualMgmtProtocol OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),
		ip(2),
		ipx(3),
		ipAndIpx(4)
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates which network transports over which
		the agent will currently accept SNMP requests."
	::= { s3AgentSw 20 }

s3AgentImageFile OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(0..64))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The name of the agent image file that the NMM loads
		at boot time.
		
		This parameter will not take effect until written to
		EEPROM (s3AgentWriteEeprom) and a reset (s3AgentReset)
		is issued.  This parameter is used only if s3AgentBootMode
		is set to use eeprom(1), s3AgentConfigLoadMode is set to
		localConfig(3) and s3LocImageLoadMode is not set to
		localBoot(3)."
	::= { s3AgentSw 21 }



-- Agent Network Protocol Group


-- Implementation of this group is mandatory for all SynOptics
--   Series 3000 agents


s3AgentIpAddr OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The Agent's administrative IP address. The
		current operational IP address can be obtained
		by the ipAdEntAddr entry in the ipAddrTable.

		This parameter will take effect only after a
		restart (s3AgentRestart) is issued. This parameter
		will not survive a reset (s3AgentReset) unless it
		is written into EEPROM (s3AgentWriteEeprom). This
		parameter is used only if the s3AgentBootMode is
		set to use EEPROM."
	::= { s3AgentIpProtocol 1 }

s3AgentNetMask OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The Agent's administrative subnet mask. The
		current operational subnet mask can be obtained
		by the ipAdEntNetMask entry in the ipAddrTable.

		This parameter will take effect only after a
		restart (s3AgentRestart) is issued. This parameter
		will not survive a reset (s3AgentReset) unless it 
		is written into EEPROM (s3AgentWriteEeprom). This
		parameter is used only if the agentBootMode is set
		to use EEPROM.

		NOTE:  The Model 331x (3313, 3313M, 3314-ST,
		3314M-ST) Ethernet NMM agents do not store this
		parameter in EEPROM, so for these agents the subnet
		mask configuration must be downloaded in the
		configuration file."
	::= { s3AgentIpProtocol 2 }

s3AgentDefaultGateway OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The Agent's administrative default gateway IP
		address. The current operational default gateway's
		IP address can be obtained from the ipRoutingTable.

		This parameter will take effect only after a
		restart (s3AgentRestart) is issued.  This parameter
		will not survive a reset (s3AgentReset) unless it 
		is written into EEPROM (s3AgentWriteEeprom).  This
		parameter is used only if the agentBootMode is set
		to use EEPROM."
	::= { s3AgentIpProtocol 3 }

s3AgentBootServerAddr OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The IP address to which the requests for boot files
		are sent. The protocol used to retrieve the boot
		files is determined by object s3AgentBootProtocol.

		This parameter will not take effect until until
		written into EEPROM (s3AgentWriteEeprom) and a
		reset (s3AgentReset) is issued. This parameter is
		used only if the s3AgentBootMode is set to use EEPROM."
	::= { s3AgentIpProtocol 4 }

s3AgentSecDefaultGateway OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The agent's administrative secondary default
		gateway IP address. This default gateway's IP
		address will be used when the primary default
		gateway (s3AgentDefaultGateway) is determined
		unreachable.

		This parameter will not survive a reset (s3AgentReset)
		unless it is written into EEPROM (s3AgentWriteEeprom)."
	::= { s3AgentIpProtocol 5 }

s3AgentPingDefaultRtrSwitch OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),
		on(2),
		off(3)
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Controls whether the agent will periodically send
		out the icmp echos (pings) to the default router(s).
		The values are:
		  other(1)...unknown or other
		  on(2)......agent will periodically send out pings
		               to the default router(s).
		  off(3).....agent won't send out the pings to the
		               default router(s)."
	::= { s3AgentIpProtocol 6}

s3AgentPingDefaultRtrTime OBJECT-TYPE
	SYNTAX	TimeTicks
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The time interval that the agent uses to send
		out the pings periodically to the default router(s)
		to check if the router(s) are still reachable."
	::= { s3AgentIpProtocol 7}

s3AgentBootRouter OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The default route IP address used at boot
		time to download the NMM's agent configuration
		and image files from the TFTP server.

		This parameter will not survive a reset
		(s3AgentReset) unless it is written into EEPROM
		(s3AgentWriteEeprom)."
	::= {  s3AgentIpProtocol  8  }



-- Agent Trap Receiver Table


-- Implementation of this group is mandatory for all SynOptics
--   Series 3000 agents


s3AgentTrapReceiverTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF S3AgentTrapReceiverEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"Table containing list of NMS's that are to receive
		traps generated by this NMM."
	::= { s3SnmpAgent 3 }

s3AgentTrapReceiverEntry OBJECT-TYPE
	SYNTAX	S3AgentTrapReceiverEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A destination address and community string to a
		particular trap server, along with a trap filter
		and entry aging capability."
	INDEX	{ s3AgentTrapRcvrNetAddress }
	::= { s3AgentTrapReceiverTable 1 }

S3AgentTrapReceiverEntry ::= SEQUENCE {
	s3AgentTrapRcvrStatus
		INTEGER,
	s3AgentTrapRcvrNetAddress
		OCTET STRING,
	s3AgentTrapRcvrComm
		OCTET STRING,
	s3AgentTrapRcvrAgeTime
		TimeTicks
	}

s3AgentTrapRcvrStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		other (1),		-- none of the following
		valid (2),		-- a valid address
		invalid (3)		-- an invalid address
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Setting this object to the value invalid(3) has
		the effect of invalidating the corresponding entry
		in the s3AgentTrapReceiverTable.  That is, it 
		effectively disassociates the address identified
		with the entry by removing the entry from the table.
		On a read the value of valid(2) should be returned
		if the entry contains a valid record, or invalid(3)
		should be returned if the entry contains an invalid
		record."
	::= { s3AgentTrapReceiverEntry 1 }

s3AgentTrapRcvrNetAddress OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(4))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"IP address for trap server that is to receive
		the trap."
	::= { s3AgentTrapReceiverEntry  2 }

s3AgentTrapRcvrComm OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(0..20))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Community string used for traps sent to this
		trap receiver."
	::= { s3AgentTrapReceiverEntry  3 }

s3AgentTrapRcvrAgeTime OBJECT-TYPE
	SYNTAX	TimeTicks
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This is the time interval used to age entries out
		of the trap receiver table.  The default value if
		not specified will be 0, or infinite, never to be
		aged out."
	::= { s3AgentTrapReceiverEntry  4 }



-- Agent Hardware Group


-- Implementation of this group is mandatory for all 
--   SynOptics Series 3000 agents



s3AgentStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		offline(1),		-- the agent is offline
		online(2)		-- the agent is online
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the NMM is online(2) and
		operating, or offline(1) (ie: not connected to the
		concentrator backplane)."
	::= { s3AgentHw 1 }

s3AgentMdaHwVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The network management module's MDA hardware
		version number  (0=Rev. A, 1=Rev. B, etc.)."
	::= { s3AgentHw 2 }

s3AgentMode OBJECT-TYPE
	SYNTAX	INTEGER {
		primary(1),		-- in primary mode
		secondary(2),		-- in secondary mode
		other(3)		-- the other values do not apply
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the NMM is operating in
		primary(1) or secondary(2) mode."
	::= { s3AgentHw 3 }

s3AgentReset OBJECT-TYPE
	SYNTAX	INTEGER {
		noReset(1),		-- not resetting
		reset(2)		-- reset
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Network management module reset status.  Writing
		a reset(2) to this object will reset the NMM and
		perform a download and restart."
	::= { s3AgentHw 4 }

s3AgentRestart OBJECT-TYPE
	SYNTAX	INTEGER {
		noRestart(1),		-- not restarting
		restart(2)		-- restart
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Network management module restart status.
		Writing a restart(2) to this object will restart
		the NMM.  This initializes all the counters,
		re-reads the EEPROM data structure and starts
		executing from the beginning of the code."
	::= { s3AgentHw 5 }

s3AgentBootMode OBJECT-TYPE
	SYNTAX	INTEGER {
		eeprom(1),
		net(2),
		otherCase(3)
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The method for obtaining boot parameter information.
		The possible values are:
		  eeprom(1)......get boot info from eeprom
		  net(2).........get boot info from remote server
		  otherCase(3)...not eeprom or net

		This parameter will not take effect until written
		into EEPROM (s3AgentWriteEeprom) and a reset
		(s3AgentReset) is issued.

		Note: In previous versions of this MIB the name
		      associated with the value '2' was 'other',
		      which implied the same meaning as it does
		      now.  Thus to prevent confusion, the name
		      for value '3' was chosen to be 'otherCase'."
	::= { s3AgentHw 6 }

s3AgentWriteEeprom OBJECT-TYPE
	SYNTAX	INTEGER {
		noWriteEeprom(1),	-- not writing EEPROM 
		writeEeprom(2)		-- write EEPROM
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Network management module EEPROM write status.
		Writing a (2) to this object will write the contents
		of current EEPROM data structure in the EEPROM."
	::= { s3AgentHw 7 }

s3AgentBaudRate OBJECT-TYPE
	SYNTAX	Gauge
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Specifies the baud rate in bits per second of
		either the internal modem or the RS-232 port.

		This parameter will take effect only after a
		restart (s3AgentRestart) is issued.  This parameter
		will not survive a reset (s3AgentReset) unless
		the specific NMM configuration file is updated
		to reflect the change."
	::= { s3AgentHw 8 }

s3AgentInitString OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(0..64))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This is the initialization string used to establish
		the out-of-band connection. (i.e. could contain the
		string ATDT,415-960-1100 for an internal or external
		modem). This is used as a hint for the network manager
		since this string is not used by the agent to initiate
		a connection to a management station.

		This parameter will take effect only after a restart
		(s3AgentRestart) is issued.  This parameter will not
		survive a reset (s3AgentReset) unless the specific
		NMM configuration file is updated to reflect
		the change."
	::= { s3AgentHw 9 }

s3AgentEepromSize OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The size of the EEPROM of the agent in units of bytes."
	::= { s3AgentHw 10 }

s3AgentEpromSize OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The size of the EPROM of the agent in units of bytes."
	::= { s3AgentHw 11 }

s3AgentDramSize OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		
		"The size of the DRAM of the agent in units of bytes."
	::= { s3AgentHw 12 }

s3AgentHexDisplay OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(0..4))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The current 4 ASCII character display of the agent.

		Agents with no hex display hardware should return a
		zero length string."
	::= { s3AgentHw 13 }

s3AgentFlashStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),	-- unknown status
		ok(2),		-- the flash device is valid
		fail(3)		-- the flash device is invalid
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates the operational status of the flash
		device of the agent.  A fail(3) indicates that either
		the flash device configuration on board is not valid
		or the flash EEPROMs on the board have failed."
	::= { s3AgentHw 14 }



-- Agent Local Image Group


-- This group is mandatory for agents with image code stored in
--   local EPROM.  Other agents should return NoSuch if asked for
--   any of the objects in this group.


s3LocImageValid OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),		-- unknown status
		localImageValid(2),	-- local image is valid
		localImageInvalid(3)	-- local image is invalid
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the agent has a valid local
		code image on board.  An EPROM checksum failure would
		cause the agent to return localImageInvalid(3)."
	::= { s3AgentLocImage 1 }

s3LocImageMajorVersion OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The major software version number of the
		locally-stored image.  This object applies only to
		agents with valid local image.  Other agents 
		should return zero."
	::= { s3AgentLocImage 2 }

s3LocImageMinorVersion OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The minor software version number of the
		locally-stored image.  This object applies only
		to agents with valid local image.  Other agents
		should return zero."
	::= { s3AgentLocImage 3 }

s3LocImageLoadMode OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),		-- unknown status
		remoteBoot(2),		-- use net, not local image,
					--   and update local image
					--   if net image is different
		localBoot(3),		-- boot from local image, not net
		localAsBackup(4),	-- try net, if fails use local,
					--   but if net is OK, then update
					--   local image when net image
					--   is different
		remoteNoUpdate(5),	-- use net, not local image,
					--   and don't update local image
		remoteNewUpdate(6),	-- use net, not local image,
					--   update local image if new
					--   image is newer
		localAutoUpdate(7)	-- check net image, if newer,
					--   then update local image,
					--   and use this image
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the agent should get code
		from the network, use a local image, or try the
		network first and then fall back to local image if 
		the network boot fails. The localBoot(3) and
		localAsBackup(4) values apply only to agents with
		local load option. Note: on agents that have
		no local storage, either remoteBoot(2), or
		remoteNoUpdate(5) may be specified, however
		the value remoteBoot(2) is prefered due to
		backwards compatibility "
	::= { s3AgentLocImage 4 }

s3LocImageActualSource OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),		-- unknown status
		remoteImage(2),		-- downloaded code from network
		localImage(3)		-- loaded code from local EPROM
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the agent loaded code from
		the network or used a local image.  When the the
		ImageLoadMode is localAsBackup, this variable
		indicates whether the network load was successful."
	::= { s3AgentLocImage 5 }

s3LocImageMaintVersion OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The maintenance software version number of the
		locally-stored image.  This object applies only
		to agents with valid local image.  Other agents
		should return zero."
	::= { s3AgentLocImage 6 }